• DocumentCode
    2134080
  • Title

    Adapting the FTT-CAN Master for multiple-bus operation

  • Author

    Silva, Valter Filipe ; Fonseca, José Alberto ; Ferreira, Joaquim

  • Author_Institution
    Aveiro Univ., Aveiro
  • Volume
    1
  • fYear
    2007
  • fDate
    23-27 June 2007
  • Firstpage
    305
  • Lastpage
    310
  • Abstract
    The controller area network is still widely used as an embedded network in safety critical applications, e.g. in the automotive domain. However, requirements have changed and dependability and bandwidth limitations led to the emergence of alternative networks such as FlexRay. Nevertheless there is still room to improve CAN to try to fulfill current requirements. FTT-CAN supports multiple buses both to provide bus media redundancy and to increase the available bandwidth. The architecture and flexibility of FTT based systems enables a tight yet flexible control of redundancy and bandwidth usage without a substantial increase on the complexity of the nodes. This paper deals with the required adaptions on the FTT-CAN master node to make it capable of handling multiple buses and presents some results derived from experimental measurements made on a reference implementation.
  • Keywords
    controller area networks; system buses; FTT-CAN master; bus media redundancy; embedded network; flexible time-triggered controller area network; multiple-bus operation; safety critical application; Automotive engineering; Bandwidth; Bit rate; Control systems; Fault tolerance; Microcontrollers; Middleware; Protocols; Redundancy; Safety;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Informatics, 2007 5th IEEE International Conference on
  • Conference_Location
    Vienna
  • ISSN
    1935-4576
  • Print_ISBN
    978-1-4244-0851-1
  • Electronic_ISBN
    1935-4576
  • Type

    conf

  • DOI
    10.1109/INDIN.2007.4384774
  • Filename
    4384774