• DocumentCode
    2139579
  • Title

    Cold-source measurements for noise figure calculation in spectrum analyzers

  • Author

    Otegi, N. ; Collantes, J.M. ; Sayed, M.

  • Author_Institution
    Electr. & Electron. Dept., Univ. of the Basque Country, Bilbao, Spain
  • fYear
    2006
  • fDate
    16-16 June 2006
  • Firstpage
    223
  • Lastpage
    228
  • Abstract
    A detailed analysis of the suitability of cold source based noise figure measurements in a spectrum analyzer is given in this paper. This technique presents some advantages in comparison to classical Y-factor techniques when dealing with problems related to device input match. A fully corrected noise figure calculation procedure, complemented with vector corrections and receiver noise calibration, is analyzed. For that, a noise calibration of the spectrum analyzer receiver, based upon analytical calculation, is given.
  • Keywords
    calibration; measurement errors; microwave measurement; spectral analysers; classical Y-factor technique comparison; cold source based noise figure measurement; microwave instrumentation; noise figure calculation procedure; receiver noise calibration; spectrum analyzer; systematic errors; vector-corrected cold-source methodology; Acoustic reflection; Calibration; Electric variables measurement; Error correction; Noise figure; Noise measurement; Performance evaluation; Power measurement; Spectral analysis; Temperature; cold-source; noise figure; noise measurements; receiver noise calibration;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    ARFTG Conference, 2006 67th
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    978-0-7803-9529-9
  • Type

    conf

  • DOI
    10.1109/ARFTG.2006.4734387
  • Filename
    4734387