Abstract
The beam position monitors, processing electronics, and VME-crate-based data acquisition system have been designed and implemented recently in the Synchrotron Radiation Research Center (SRRC). The beam position monitor is composed of four button-type electrodes that are welded on the vacuum chamber directly. The switched detector processing electronics and the high speed data acquisition system were chosen for fast beam position measurement due to the requirements of the global harmonic orbit correction and the local beam position feedback system. The beam position measurement system will provide fast and accurate beam position information for the 1.3 GeV storage ring. The orbit acquisition rate is about 500 orbit/s.<>
Keywords
data acquisition; electron accelerators; nuclear electronics; particle beam diagnostics; storage rings; Synchrotron Radiation Research Center; VME-crate-based data acquisition system; beam monitoring; beam position monitors; fast beam position measurement; global harmonic orbit correction; high speed data acquisition system; local beam position feedback system; particle beam diagnostics; processing electronics; storage ring; switched detector processing electronics; Calibration; Data acquisition; Electrodes; Extraterrestrial measurements; Feedback; Position measurement; Signal processing; Storage rings; Structural beams; Synchrotron radiation;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location
San Francisco, CA, USA
Print_ISBN
0-7803-0135-8
Type
conf
DOI
10.1109/PAC.1991.164565
Filename
164565
Link To Document