• DocumentCode
    2140160
  • Title

    Multifrequency device for measurement of the complex electrical bio-impedance-design and application

  • Author

    Palko, T. ; Bialokoz, F. ; Weglarz, J.

  • Author_Institution
    Inst. of Precision & Biomed. Eng., Warsaw Univ. of Technol., Poland
  • fYear
    1995
  • fDate
    15-18 Feb 1995
  • Firstpage
    16438
  • Lastpage
    16803
  • Abstract
    A multifrequency device for measurement of the modulus and phase shift of complex electrical impedance of the biological tissue has been designed. Impedance measurement is based on the tetrapolar current method with the current amplitude of 1 mA. Phase is obtained using of the modified “zero-crossing” method. The device operates in the frequency range from 2 kHz to 200 kHz (in two sub-ranges) with manual and automatic frequency control. The impedance device was used for the measurement of the modulus |Z0| and phase shift φ of the transthoracic impedance by Kubicek´s method in the frequency range of 2 to 200 kHz the mean values of |Z0| changes from 30.7 to 20.2 Ω and φ respectively from 4.9 to 10.4°. In the narrower range usually used in impedance cardiography (20-100 kHz) the change of φ is 4°. This indicates a necessity to establish a standard for the transthoracic impedance measurement in impedance cardiography method and to use only one chosen frequency. The device can be used for bioimpedance spectroscopic measurements, determination of the extracellular fluids, examination of ΔZ and Δφ due to ventilation or motion of the heart
  • Keywords
    bioelectric phenomena; biomedical equipment; biomedical measurement; cardiology; electric impedance imaging; electric impedance measurement; 1 mA; 2 to 200 kHz; 30.7 to 20.2 ohm; Kubicek´s method; bioimpedance spectroscopic measurements; clinical practice; complex electrical bioimpedance measurement; extracellular fluids determination; heart motion; impedance cardiography method; modified zero-crossing method; multifrequency device; pathology; physiological research; tetrapolar current method; transthoracic impedance measurement; ventilation; Automatic frequency control; Bioimpedance; Biological tissues; Cardiography; Electric variables measurement; Frequency measurement; Impedance measurement; Measurement standards; Phase measurement; Spectroscopy;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1995 and 14th Conference of the Biomedical Engineering Society of India. An International Meeting, Proceedings of the First Regional Conference., IEEE
  • Conference_Location
    New Delhi
  • Print_ISBN
    0-7803-2711-X
  • Type

    conf

  • DOI
    10.1109/RCEMBS.1995.508682
  • Filename
    508682