DocumentCode :
2141510
Title :
Upgrades to the Fermilab flying wire systems
Author :
Zagel, J. ; Hahn, A.A. ; Jackson, G. ; Johnson, T. ; Martin, K. ; Misek, J. ; Wang, X.Q. ; Ye, W.
Author_Institution :
Fermi Nat. Accel. Lab., Batavia, IL, USA
fYear :
1991
fDate :
6-9 May 1991
Firstpage :
1174
Abstract :
Flying wire systems have been installed in the Fermilab main ring, Tevatron, booster, and accumulator to measure the transverse beam profiles. During the recent shut down, many improvements were incorporated to increase the reliability of the hardware, software, and data obtained from their operation. These improvements include adding a double fork to the Tevatron systems, developing a new scintillator/photomultiplier tube combination, and a broken wire monitor. In addition an analysis of the motion control was performed to understand the frequent operational problems encountered. A complete test system has been assembled incorporating a laser to simulate the beam. It will serve as a test bed for new ideas and software development.<>
Keywords :
particle beam diagnostics; proton accelerators; synchrotrons; Fermilab flying wire systems; Fermilab main ring; Tevatron; accumulator; beam monitoring; booster; broken wire monitor; hardware; particle beam diagnostics; reliability; software; transverse beam profiles; Assembly systems; Hardware; Laser beams; Monitoring; Motion control; Performance analysis; Photomultipliers; Software testing; System testing; Wire;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location :
San Francisco, CA, USA
Print_ISBN :
0-7803-0135-8
Type :
conf
DOI :
10.1109/PAC.1991.164571
Filename :
164571
Link To Document :
بازگشت