DocumentCode :
2141798
Title :
An integrated flexible implantable L-glutamate sensor
Author :
Cao, Hung ; Peng, Yuan-Bo ; Chiao, Jung-Chih
Author_Institution :
Electr. Eng. Dept., Univ. of Texas at Arlington, Arlington, TX, USA
fYear :
2010
fDate :
1-4 Nov. 2010
Firstpage :
2346
Lastpage :
2350
Abstract :
In this work, we have developed a fully integrated implantable probe on polyimide-film substrate for sensing neurotransmitters and recording extracellular action potentials simultaneously. The flexibility of the probe helps to prevent scar forming in tissues aiming for long-term in vivo monitoring. An Ag/AgCl reference electrode was integrated in the same probe with the Au/Cr or Pt/Cr working electrodes, which presented an integrated, compact and robust system. Several electrode configurations have been designed for implantation at various locations in the central nervous system. The prototype device for proof of principle is an enzyme-based electrochemical L-glutamate sensor using L-glutamate oxidase. A comparison between Au and Pt thin films was conducted by cyclic voltammtry. The enzyme was deposited with a multiple-step process on the working electrodes followed by meta-Phenylenediamine coating for better selectivity. The self-referencing technique was also used to enhance both the limit of detection and selectivity. The assembled sensors were calibrated and tested at various concentrations of L-glutamate at the presence of interfering molecules showing good sensitivity and selectivity.
Keywords :
bioelectric potentials; biomedical materials; biosensors; electrochemical electrodes; electrochemical sensors; molecular biophysics; neurophysiology; polymer films; prosthetics; voltammetry (chemical analysis); L-glutamate oxidase; central nervous system; cyclic voltammetry; electrode configurations; enzyme based electrochemical L-glutamate sensor; extracellular action potential recording; flexible L-glutamate sensor; gold thin films; gold-chromium working electrodes; implantable L-glutamate sensor; integrated L-glutamate sensor; long term in vivo monitoring; meta-phenylenediamine coating; neurotransmitter sensing; platinum thin films; platinum-chromium working electrodes; polyimide film substrate; self referencing technique; silver-silver chloride reference electrode;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Sensors, 2010 IEEE
Conference_Location :
Kona, HI
ISSN :
1930-0395
Print_ISBN :
978-1-4244-8170-5
Electronic_ISBN :
1930-0395
Type :
conf
DOI :
10.1109/ICSENS.2010.5690943
Filename :
5690943
Link To Document :
بازگشت