• DocumentCode
    2142782
  • Title

    Design of the AGS Booster ionization profile monitor

  • Author

    Stillman, A.N. ; Thern, R.E. ; Witkover, R.L. ; Van Zwienen, W.H.

  • Author_Institution
    Brookhaven Nat. Lab., Upton, NY, USA
  • fYear
    1991
  • fDate
    6-9 May 1991
  • Firstpage
    1189
  • Abstract
    The Alternating Gradient Synchrotron (AGS) booster ionization profile monitor (IPM) must operate in a vacuum of about 3*10/sup -/0/sup 11/ Torr. The authors present details of the design of the profile monitor. The ultra-high vacuum imposes certain requirements on detector gain and restrictions on construction techniques. Each detector is a two-stage microchannel plate with an integral substrate containing sixty-four printed anodes. Formed electrodes provide uniform collection fields without the use of resistors, which would be unacceptable in these vacuum conditions. An ultraviolet light calibrates the detector in its permanent mounting. An extra set of electrodes performs a first order correction to the perturbations imposed by the horizontal and vertical collection electrodes.<>
  • Keywords
    particle beam diagnostics; position sensitive particle detectors; proton accelerators; synchrotrons; AGS Booster ionization profile monitor; Alternating Gradient Synchrotron; beam monitoring; collection electrodes; first order correction; particle beam diagnostics; two-stage microchannel plate; Anodes; Detectors; Electrodes; Electrons; Ionization; Microchannel; Monitoring; Structural beams; Vacuum technology; Wires;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
  • Conference_Location
    San Francisco, CA, USA
  • Print_ISBN
    0-7803-0135-8
  • Type

    conf

  • DOI
    10.1109/PAC.1991.164576
  • Filename
    164576