DocumentCode
2144306
Title
Evaluation of shielded enclosure leak detection system (SELDS) with non-conventional excitation for shield weld quality monitoring
Author
Nielsen, Paul ; Croisant, William ; McInerney, M.
Author_Institution
R&D Center Constr. Eng. Res. Lab., Champaign, IL, USA
Volume
1
fYear
2003
fDate
18-22 Aug. 2003
Firstpage
460
Abstract
In this paper, we describe laboratory evaluations of nonconventional shielded enclosure leak detection system (SELDS) test techniques for determining/monitoring welded seam quality for EMI/RFI shielded construction. These techniques involve a "transmission line" seam excitation rather than the usual "circuit" excitation. The method of evaluation and results are presented.
Keywords
electromagnetic shielding; exciters; leakage currents; radiation detection; radiofrequency interference; transmission lines; EMI; RFI; SELDS test methods; circuit excitation; elecromagnetic interference; nonconventional excitation; radiofrequency interference; seam excitation; shield weld quality monitoring; shielded construction; shielded enclosure leak detection; transmission line; welded seam quality; Floors; Laboratories; Leak detection; Monitoring; Radio frequency; Research and development; Steel; System testing; Welding; Wires;