Abstract :
We report our experience in obtaining high voltages up to 1 MV required for the acceleration of D- beams. We find that satisfactory voltage holding at this level can be obtained by adding gas up to a few 10-4 mb. Obtaining the required voltage at lower pressures is made cumbersome by the appearance of leakage (or dark) currents. Since the reduction of the dark current by conditioning is very time consuming the most practical remedy is the reduction of the cathode and anode surfaces of the system.
Keywords :
anodes; cathodes; electrostatic accelerators; particle beam fusion accelerators; 1 MV; Cadarache ion beam facility; D- beams acceleration; anode surfaces reduction; cathode surfaces reduction; dark currents; high voltages; leakage currents; voltage holding; Acceleration; Dark current; Dielectrics and electrical insulation; Electrostatics; Insulators; Ion beams; Particle beams; Resistors; Vacuum systems; Voltage;