Title :
Low frequency correlation of radiated emission measurements between a semi-anechoic chamber and an OATS or a weather protected sites
Author :
Jones, Clifford Eugene ; Schramm, David
Author_Institution :
Intertek Testing Services, Lexington, KY, USA
Abstract :
This paper documents the results of a measurement study to determine if low frequency radiated electric field emissions (10 kHz-30 MHz) and radiated magnetic field emissions (60 Hz-30 MHz) can be suitably measured in a 10 meter absorber lined (semi-anechoic) chamber.
Keywords :
anechoic chambers (electromagnetic); electric fields; electromagnetic compatibility; magnetic fields; open area test sites; 0.01 to 30 MHz; 10 m; 60 Hz to 30 MHz; OATS; electric field emissions; low frequency correlation; radiated emission measurements; radiated magnetic field emissions; semianechoic chamber; weather protected sites; Area measurement; Electric variables measurement; Frequency measurement; Laboratories; Magnetic field measurement; Open area test sites; Performance evaluation; Protection; Size measurement; Testing;
Conference_Titel :
Electromagnetic Compatibility, 2003 IEEE International Symposium on
Print_ISBN :
0-7803-7835-0
DOI :
10.1109/ISEMC.2003.1236684