DocumentCode
2146495
Title
The AGS booster beam loss monitor system
Author
Beadle, E.R. ; Bennett, G.W. ; Witkover, R.L.
Author_Institution
Brookhaven Nat. Lab., Upton, NY, USA
fYear
1991
fDate
6-9 May 1991
Firstpage
1231
Abstract
A beam loss monitor system has been developed for the Brookhaven National Laboratory booster accelerator, and was designed for use with intensities of up to 1.5*10/sup 13/ protons and carbon to gold ions at 50-3*10/sup 9/ ions per pulse. The authors discuss the design, construction, and operation of the system. This system achieves a significant advance over the present AGS (Alternating Gradient Synchrotron) system by improving the sensitivity, dynamic range, and data acquisition. In addition to the large dynamic range achievable, it is adaptively shifted when high losses are detected. The system uses up to 80 argon-filled ion chambers as detectors, as well as newly designed electronics for processing and digitizing detector outputs. The hardware simultaneously integrates each detector output, interfaces to the beam interrupt systems, and digitizes all 80 channels to 12 b at 170 kHz.<>
Keywords
ion accelerators; particle beam diagnostics; proton accelerators; synchrotrons; AGS booster beam loss monitor system; Alternating Gradient Synchrotron; beam interrupt systems; data acquisition; electronics; particle beam diagnostics; Data acquisition; Detectors; Dynamic range; Gold; Ion accelerators; Monitoring; Particle beams; Proton accelerators; Structural beams; Synchrotrons;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location
San Francisco, CA, USA
Print_ISBN
0-7803-0135-8
Type
conf
DOI
10.1109/PAC.1991.164590
Filename
164590