Abstract :
A beam position monitor system has been developed and used in the commissioning of Brookhaven´s Linac-to-Booster transfer line. This line transports a chopped, RF modulated H/sup -/ beam from the 200-MeV Linac to the AGS Booster. Over a 15-dB dynamic range in beam current, the position monitor system provides a real-time, normalized position signal with an analog bandwidth of about 20 MHz. Seven directional coupler style pickups are installed in the line with each pickup sensing both horizontal and vertical position. A system overview is presented along with results from the commissioning experience.<>
Keywords :
ion accelerators; linear accelerators; particle beam diagnostics; proton accelerators; synchrotrons; AGS Linac to Booster transfer line; beam current; commissioning; directional coupler style pickups; normalized position signal; position monitor system; Amplitude modulation; Control systems; Electrodes; Linear particle accelerator; Monitoring; Optical modulation; Phase modulation; Radio frequency; Stripline; Transfer functions;
Conference_Titel :
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location :
San Francisco, CA, USA
Print_ISBN :
0-7803-0135-8
DOI :
10.1109/PAC.1991.164657