DocumentCode
2150508
Title
Correction of skew-quadrupole errors in RHIC
Author
Dell, G.F. ; Hahn, H. ; Lee, S.Y. ; Parzen, G. ; Tepikian, S.
Author_Institution
Brookhaven Nat. Lab., Upton, NY, USA
fYear
1991
fDate
6-9 May 1991
Firstpage
1627
Abstract
The correction scheme for skew-quadrupole (a/sub 1/) errors in the Relativistic Heavy Ion Collider is presented. The a/sub 1/ errors result from fabrication and from installation errors. At the selected betatron tune of nu /sub x/=28.826 and nu /sub y/-28.820, the principal resonances driven by a/sub 1/ errors are nu /sub x/- nu /sub y/=0, the sum resonances near nu /sub x/+ nu /sub y/ which cause residual tune splitting and distortion of beta function, and nu /sub y/=28 and 29 which cause vertical dispersion. Skew quadrupole correctors located in the insertions and arcs will be used to correct the coupling and sum resonances and, if required, separate correctors in the arcs could be used for vertical dispersion correction.<>
Keywords
beam handling equipment; beam handling techniques; ion accelerators; synchrotrons; RHIC; Relativistic Heavy Ion Collider; a/sub 1/ errors result; arcs; beta function; installation errors; principal resonances; residual tune splitting; selected betatron tune; skew-quadrupole errors; sum resonances; vertical dispersion; Coils; Dispersion; Error correction; Fabrication; Laboratories; Measurement errors; Power supplies; Resonance; Sorting; Structural beams;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location
San Francisco, CA, USA
Print_ISBN
0-7803-0135-8
Type
conf
DOI
10.1109/PAC.1991.164725
Filename
164725
Link To Document