DocumentCode :
2159444
Title :
Clinical analysis for cardiovascular disease by calculating Stiffness Index, Cardiac Output from pulse wave
Author :
Fan, Zhaopeng ; Zhang, Gong ; Liao, Simon
Author_Institution :
Univ. of Winnipeg, Winnipeg, MB
fYear :
2009
fDate :
3-6 May 2009
Firstpage :
478
Lastpage :
481
Abstract :
We inspected the relationship between cardiovascular disease and clinical pulse wave data. The pulse wave data were collected from the Department of Cardiology at Shandong Provincial Hospital by infrared light pulse wave sensor. Based on the risk factors, Stiffness Index (SI) and Cardiac Output (CO) are utilized as the characteristics to detect cardiovascular disease. The results show a close relationship between cardiovascular disease and the derived pulse wave characteristics.
Keywords :
cardiovascular system; diseases; haemodynamics; cardiac output; cardiovascular disease; clinical pulse wave data; haemodynamics; infrared light pulse wave sensor; risk factors; stiffness index; Arteries; Atherosclerosis; Blood flow; Cardiology; Cardiovascular diseases; Clinical diagnosis; Fingers; Hospitals; Infrared sensors; Pulse measurements; Cardiac Output; Cardiovascular Disease; Stiffness Index; adjusted SI; pulse wave;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical and Computer Engineering, 2009. CCECE '09. Canadian Conference on
Conference_Location :
St. John´s, NL
ISSN :
0840-7789
Print_ISBN :
978-1-4244-3509-8
Electronic_ISBN :
0840-7789
Type :
conf
DOI :
10.1109/CCECE.2009.5090180
Filename :
5090180
Link To Document :
بازگشت