• DocumentCode
    2167998
  • Title

    Full-scale test on domestic sewage treatment with combination aeration MBr integration equipment

  • Author

    Hu, Fengping ; Wan, Cong ; Chen, Wei ; Zhu, Pei

  • Author_Institution
    Sch. of Civil Eng. & Archit., East China Jiaotong Univ., Nanchang, China
  • fYear
    2012
  • fDate
    19-21 Oct. 2012
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Use combination aeration membrane bioreactor for urban sewage processing, when influent CODCr, BOD5, NH3-N concentration ranged:53.15~978.50 mg/L, 28.23~431.55 mg/L, 4.14~37.78 mg/L, when the hydraulic retention time (HRT) for 4 h, 6 h, 8 h, CODCr, BOD5 and NH3-N the average removal efficiencies were: above 90%, above 95%, above 90%, the best HRT for 6 h. Stable effluent quality, its range was CODCr: 3.5~30 mg/L; BOD5: below 5 mg/L; NH3-N: below 5 mg/L, effluent quality is better than The Reuse of Urban Recycling Water-Water Quality Standard for Urban Miscellaneous Water Consumption(GB/T 18920-2002).
  • Keywords
    ammonia; bioreactors; effluents; environmental testing; sewage treatment; standards; BOD; COD; NH3-N; The Reuse of Urban Recycling Water-Water Quality Standard for Urban Miscellaneous Water Consumption; ammonia-nitrogen concentration; basic oxygen demand; chemical oxygen demand; combination aeration MBR integration equipment; domestic sewage treatment; effluent quality; full-scale test; hydraulic retention time; membrane bioreactor; time 6 h; urban sewage processing; Biomembranes; Educational institutions; Effluents; Standards; Wastewater; Water conservation; Water pollution; HRT; combination aeration MBR; domestic sewage; integration;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Geomatics for Integrated Water Resources Management (GIWRM), 2012 International Symposium on
  • Conference_Location
    Lanzhou, Gansu
  • Print_ISBN
    978-1-4673-1283-7
  • Type

    conf

  • DOI
    10.1109/GIWRM.2012.6349589
  • Filename
    6349589