• DocumentCode
    2168784
  • Title

    Space charge accumulation in water tree degraded LDPE and its evaluation by TSC method

  • Author

    Kawamura, Hideaki ; Nawata, Masahito

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Meijo Univ., Nagoya, Japan
  • Volume
    1
  • fYear
    1994
  • fDate
    3-8 Jul 1994
  • Firstpage
    420
  • Abstract
    The space charge in water tree degraded LDPE has been measured by the thermally stimulated current (TSC) method. The shape of the TSC spectra does not change with the degradation of polymeric insulation containing water trees, but the TSC peak increases linearly with the increase of the length of the water tree. It is shown that the TSC measuring method can adapt to evaluate the degradation caused by water treeing
  • Keywords
    Charge measurement; Current measurement; Dielectrics and electrical insulation; Electrodes; Needles; Plastic insulation; Polymers; Space charge; Thermal degradation; Trees - insulation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Properties and Applications of Dielectric Materials, 1994., Proceedings of the 4th International Conference on
  • Conference_Location
    Brisbane, Qld.
  • Print_ISBN
    0-7803-1307-0
  • Type

    conf

  • DOI
    10.1109/ICPADM.1994.414030
  • Filename
    414030