Title :
Space charge accumulation in water tree degraded LDPE and its evaluation by TSC method
Author :
Kawamura, Hideaki ; Nawata, Masahito
Author_Institution :
Dept. of Electr. & Electron. Eng., Meijo Univ., Nagoya, Japan
Abstract :
The space charge in water tree degraded LDPE has been measured by the thermally stimulated current (TSC) method. The shape of the TSC spectra does not change with the degradation of polymeric insulation containing water trees, but the TSC peak increases linearly with the increase of the length of the water tree. It is shown that the TSC measuring method can adapt to evaluate the degradation caused by water treeing
Keywords :
Charge measurement; Current measurement; Dielectrics and electrical insulation; Electrodes; Needles; Plastic insulation; Polymers; Space charge; Thermal degradation; Trees - insulation;
Conference_Titel :
Properties and Applications of Dielectric Materials, 1994., Proceedings of the 4th International Conference on
Conference_Location :
Brisbane, Qld.
Print_ISBN :
0-7803-1307-0
DOI :
10.1109/ICPADM.1994.414030