• DocumentCode
    2175533
  • Title

    The effect of charge elimination by corona discharge on the characteristics of contact charging of high polymers

  • Author

    Hase, Tetuhiro ; Hiyoshi, Isao ; Murata, Yuji

  • Author_Institution
    Fac. of Sci. & Technol., Sci. Univ. of Tokyo, Japan
  • Volume
    2
  • fYear
    1995
  • fDate
    8-12 Oct 1995
  • Firstpage
    1529
  • Abstract
    Charge elimination using ions generated by corona discharge in N 2 gas is investigated. An electrode system composed of a needle and a disc electrode was used for a charge eliminator and Ions are took out of a small aperture of the disk by gas flow. The electrostatic charge on both sides of polymer film is satisfactorily eliminated at the same time using two eliminators. When the sample film is directly exposed to corona at the point of needle during charge eliminating treatment, it is observed that, after this treatment, the contact charging characteristics of polyethylene changed seriously. When the sample surface is indirectly exposed by conveying ions to the sample using a bent pipe, this effect can be avoided
  • Keywords
    corona; electrodes; electrostatics; polymers; N2; charge elimination; contact charging; corona discharge; disc electrode; electrode system; electrostatic charge; gas flow; high polymers; needle; Apertures; Corona; Electrodes; Electrostatics; Fluid flow; Needles; Plastic films; Polyethylene; Polymer films; Surface charging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industry Applications Conference, 1995. Thirtieth IAS Annual Meeting, IAS '95., Conference Record of the 1995 IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    0197-2618
  • Print_ISBN
    0-7803-3008-0
  • Type

    conf

  • DOI
    10.1109/IAS.1995.530484
  • Filename
    530484