• DocumentCode
    2176245
  • Title

    Operation of thermoelectric module in enforced regime

  • Author

    Babin, Victor P. ; Takhistov, Philip Yu

  • Author_Institution
    Found. "FRETE", St. Petersburg, Russia
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    470
  • Lastpage
    471
  • Abstract
    Enforced regime is so called regime of cooling when the temperature of heat-absorbing module´s side T0 is more than the temperature of heat-releasing side T1. This regime is used for cooling objects with high initial temperature and characterized by high values of COP. In this work the analytical formula for maximum cooling capacity of system is given with taking into consideration heat sink thermal conductance
  • Keywords
    cooling; heat sinks; thermal analysis; thermal conductivity; thermoelectric conversion; cooling; enforced regime operation; heat sink thermal conductance; heat-absorbing module temperature; maximum cooling capacity; thermoelectric module; Cooling; Electric resistance; Equations; Heat sinks; Heat transfer; Temperature; Thermal conductivity; Thermal factors; Thermal resistance; Thermoelectricity;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Thermoelectrics, 2001. Proceedings ICT 2001. XX International Conference on
  • Conference_Location
    Beijing
  • ISSN
    1094-2734
  • Print_ISBN
    0-7803-7205-0
  • Type

    conf

  • DOI
    10.1109/ICT.2001.979932
  • Filename
    979932