DocumentCode :
2176434
Title :
A study of partial discharges in air with an ultra-wideband signal detector
Author :
Levy, Alain F S ; Filho, Orsino B Oliveira ; Forster, Eric O.
Author_Institution :
CEPEL, Electr. Power Res. Center, Rio de Janeiro, Brazil
Volume :
2
fYear :
1994
fDate :
3-8 Jul 1994
Firstpage :
558
Abstract :
Partial discharges in air have been the subject of many studies. Here, a study of individual partial discharges taking place in the nanosecond range has been performed to gain more definite information on their temporal characteristics. The total charge of such a single pulse was compared with the results obtained with a commercial partial discharge measuring system. A significant difference in the total charge measured by these two systems has been found. The significance of these findings is discussed in detail. Reference is also made to the pulsating characteristics observed for the individual current signals
Keywords :
air insulation; corona; insulation testing; partial discharges; signal detection; test equipment; air; current signals; measuring system; nanosecond range; partial discharges; pulsating characteristics; temporal characteristics; testing; ultra-wideband signal detector; Bandwidth; Books; Circuit testing; Corona; Detectors; Impedance; Partial discharges; Pulse measurements; Signal detection; Ultra wideband technology;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Properties and Applications of Dielectric Materials, 1994., Proceedings of the 4th International Conference on
Conference_Location :
Brisbane, Qld.
Print_ISBN :
0-7803-1307-0
Type :
conf
DOI :
10.1109/ICPADM.1994.414071
Filename :
414071
Link To Document :
بازگشت