DocumentCode :
2177427
Title :
Harmonic analysis of Fermilab Main Ring quadrupoles
Author :
Brown, B.C. ; Mazur, P.O. ; Ostiguy, J.-F. ; Pruss, S.M. ; Turkot, F.
Author_Institution :
Fermi Nat. Accel. Lab., Batavia, IL, USA
fYear :
1991
fDate :
6-9 May 1991
Firstpage :
2128
Abstract :
Utilizing a rotating coil harmonic measurement system, a sample of more than 35 Fermilab Main Ring quadrupoles has been measured. The asymmetric design of these magnets provides many easily measured harmonic coefficients. Results for harmonic coefficients at various excitation levels are presented. Since the magnets were designed with an elliptical aperture, the only symmetries which are preserved by design are the top/bottom and left/right symmetries. This permits a much richer spectrum of harmonic components than a symmetric quadrupole. Overall the harmonic measurement system makes it possible to characterize the gradient errors for Main Ring quadrupoles throughout the range of interest for current operation or main injector use.<>
Keywords :
beam handling equipment; electromagnets; magnetic field measurement; proton accelerators; synchrotrons; Fermilab Main Ring; asymmetric design; harmonic coefficients; harmonic components; proton synchrotron; quadrupole magnets; rotating coil harmonic measurement system; Apertures; Coils; Coordinate measuring machines; Harmonic analysis; Magnetic field measurement; Magnets; Operational amplifiers; Probes; Rotation measurement; Shape measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location :
San Francisco, CA, USA
Print_ISBN :
0-7803-0135-8
Type :
conf
DOI :
10.1109/PAC.1991.164888
Filename :
164888
Link To Document :
بازگشت