Abstract :
A new procedure for direct electric measurement of total losses in permanent magnet brushless AC machines is presented in this paper. The procedure is based on a back-to-back mechanical and electrical connection to allow for a single three-phase converter supply. The motors can be driven in speed as an equivalent machine, the current in the motors depends on the physical angular displacement between the two rotors. The power supplied by the converter in steady-state is the total power dissipated by the two motors. A simple algorithm to identify the current to mechanical angle relationship at a given speed is proposed. The proposed procedure is validated by an experimental setup adopting two low power torque motors.
Keywords :
AC machines; brushless machines; loss measurement; permanent magnet machines; power convertors; torque motors; PM brushless machines; back-to-back mechanical connection; current to mechanical angle relationship; direct electric losses measurement; electrical connection; equivalent machine; low power torque motors; permanent magnet brushless AC machines; physical angular displacement; single three-phase converter supply; Inverters; Iron; Loss measurement; Synchronous motors; Torque; Vectors; Brushless machines; Loss measurement; Permanent magnet machines; Power measurement; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines (ICEM), 2012 XXth International Conference on
Conference_Location :
Marseille
Print_ISBN :
978-1-4673-0143-5
Electronic_ISBN :
978-1-4673-0141-1
Type :
conf
DOI :
10.1109/ICElMach.2012.6350103
Filename :
6350103
Link To Document :
بازگشت