DocumentCode :
2182179
Title :
High-frequency calibration of inductive voltage dividers
Author :
Robinson, I.A. ; Bryant, S.
Author_Institution :
Nat. Phys. Lab., Teddington, UK
fYear :
1994
fDate :
June 27 1994-July 1 1994
Firstpage :
492
Abstract :
We have constructed a semi-automated system for calibrating inductive voltage dividers (IVDs) in the frequency range 5-300 kHz, with a target measurement uncertainty of 1 ppm at 300 kHz.<>
Keywords :
calibration; inductors; voltage dividers; voltage measurement; windings; 5 to 300 kHz; high-frequency calibration; inductive voltage dividers; reference dividers; semiautomated system; target measurement uncertainty; voltage measurement; Calibration; Capacitance; Coaxial components; Laboratories; Plugs; Relays; Sockets; Switches; Testing; Zero voltage switching;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements, 1994. Digest., 1994 Conference on
Conference_Location :
Boulder, CO, USA
Print_ISBN :
0-7803-1984-2
Type :
conf
DOI :
10.1109/CPEM.1994.333202
Filename :
333202
Link To Document :
بازگشت