DocumentCode
2182344
Title
The influence of the broken bar fault on the magnetic field and electromagnetic torque in 3-phase induction motors
Author
Spyropoulos, Dionysios V. ; Gyftakis, Konstantinos N. ; Kappatou, Joya ; Mitronikas, Epaminondas D.
fYear
2012
fDate
2-5 Sept. 2012
Firstpage
1868
Lastpage
1874
Abstract
Broken bar faults are common in induction cage motors and can cause a variety of problems. This is the reason why there is continuous research on techniques for prompt detection. In this work a study of the influences of the broken bar fault to the electromagnetic characteristics of the induction motor is presented, using an asynchronous cage motor and FEM analysis. To this direction two models have been created and studied: a healthy one and a model with a broken bar fault. Additionally, a new approach on the detection of the broken rotor bar fault through the electromagnetic torque monitoring is suggested.
Keywords
finite element analysis; induction motors; torque; 3-phase induction motors; FEM analysis; broken bar fault; electromagnetic torque; induction cage motors; magnetic field; prompt detection; Air gaps; Harmonic analysis; Induction motors; Rotors; Stators; Torque; Broken Rotor Bar; Fault detection; Fault diagnosis; Finite Element Methods; Induction Motors; Torque Measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines (ICEM), 2012 XXth International Conference on
Conference_Location
Marseille
Print_ISBN
978-1-4673-0143-5
Electronic_ISBN
978-1-4673-0141-1
Type
conf
DOI
10.1109/ICElMach.2012.6350136
Filename
6350136