• DocumentCode
    2182431
  • Title

    Three-level NPC inverter fault diagnosis by the Average Current Park´s Vector approach

  • Author

    Abadi, Mohsen Bandar ; Mendes, A.M.S. ; Cruz, S.M.A.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Univ. of Coimbra & Inst. of Telecomun., Coimbra, Portugal
  • fYear
    2012
  • fDate
    2-5 Sept. 2012
  • Firstpage
    1893
  • Lastpage
    1898
  • Abstract
    This paper presents a diagnosis method for the detection and location of open-circuit faults in 3-Level NPC inverters with SVPWM modulation scheme based on even-order harmonic elimination. The performance of the NPC inverter under normal and faulty conditions is firstly investigated both by simulation and experiments. Afterwards, a method for inverter diagnosis is proposed, based on the Average Current Park´s Vector. This method proved to be capable of detecting and locating the phase and the semiconductor pair where the faulty IGBT is located.
  • Keywords
    PWM invertors; fault diagnosis; insulated gate bipolar transistors; power bipolar transistors; power conversion harmonics; SVPWM modulation scheme; average current park vector approach; even-order harmonic elimination; faulty IGBT; open-circuit faults; semiconductor pair; three-level NPC inverter fault diagnosis; Circuit faults; Fault diagnosis; Induction motors; Insulated gate bipolar transistors; Inverters; Switches; Vectors; 3-Level NPC inverters; Average Current Park´s Vector; Fault diagnosis; open-circuit Faults;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines (ICEM), 2012 XXth International Conference on
  • Conference_Location
    Marseille
  • Print_ISBN
    978-1-4673-0143-5
  • Electronic_ISBN
    978-1-4673-0141-1
  • Type

    conf

  • DOI
    10.1109/ICElMach.2012.6350140
  • Filename
    6350140