• DocumentCode
    2183057
  • Title

    A calibration method of microwave noise sources with different types of connectors

  • Author

    Kato, Y.

  • Author_Institution
    Electrotech. Lab., Ibaraki, Japan
  • fYear
    1994
  • fDate
    June 27 1994-July 1 1994
  • Firstpage
    252
  • Lastpage
    253
  • Abstract
    A method to calibrate a microwave noise source with a connector different from that of the standards has been proposed. This method requires two adaptors for mating the connector of the unknown to those of the standards and a radiometer. The measurement principle and a measurement equation are expressed.<>
  • Keywords
    calibration; electric connectors; electric noise measurement; electric variables measurement; measurement standards; microwave measurement; noise generators; calibration; connectors; measurement equation; measurement principle; measurement standards; microwave noise sources; radiometer; Calibration; Coaxial components; Connectors; Equations; Laboratories; Microwave radiometry; Microwave theory and techniques; Noise measurement; Signal to noise ratio; Temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 1994. Digest., 1994 Conference on
  • Conference_Location
    Boulder, CO, USA
  • Print_ISBN
    0-7803-1984-2
  • Type

    conf

  • DOI
    10.1109/CPEM.1994.333236
  • Filename
    333236