Abstract :
New, efficient measurement techniques are used to adequately characterize the actual performance of the new generation of programmable equivalent time sequential sampling oscilloscopes. These instruments provide new time interval measurement capabilities with increased repeatability and accuracy. Subpicosecond repeatability for risetime measurements of fast step generators (20 ps transition time) has been observed. A typical timebase related peak error of 3 ps for short time interval measurements (up to tens of ns) has been shown. A brief introduction on the horizontal timebase error sources is followed by the description of the automated measurement techniques. Finally actual measurement results are shown using the described techniques.<>
Keywords :
measurement errors; oscilloscopes; time bases; time measurement; 20 ps; automated measurement; fast step generators; horizontal timebase error sources; picosecond resolution; programmable equivalent time sequential sampling oscilloscopes; risetime measurements; subpicosecond repeatability; time interval measurement techniques; Clocks; Delay effects; Instruments; Measurement techniques; Oscillators; Oscilloscopes; Sampling methods; Time measurement; Timing; Transfer functions;