• DocumentCode
    2185054
  • Title

    Minimizing time dilation shift in Penning trap atomic clocks

  • Author

    Tan, J.N. ; Bollinger, J.J. ; Wineland, D.J.

  • Author_Institution
    Time & Frequency Div., NIST, Boulder, CO, USA
  • fYear
    1994
  • fDate
    June 27 1994-July 1 1994
  • Firstpage
    436
  • Lastpage
    437
  • Abstract
    The time dilation shift is expected to give the largest systematic uncertainty in an ion clock. We show that, in a Penning trap, it can be minimized if the ions are prepared in a special spheroid. The results apply directly for one ion species and approximately for sympathetically cooled systems.<>
  • Keywords
    atomic clocks; beam handling techniques; frequency measurement; frequency stability; measurement standards; particle traps; radiation pressure (atoms); NIST; Penning trap atomic clocks; frequency standard; ion clock; minimisation; spheroid; sympathetically cooled systems; time dilation shift; uncertainty; Atomic clocks; Cooling; Frequency conversion; Magnetic confinement; NIST; Plasma confinement; Radio frequency; Signal to noise ratio; Stability; Uncertainty;