Abstract
This paper describes a study of thermal voltage converters (TVCs) at voltages above 500 V and at frequencies up to 100 kHz. The effects of aging and dielectric loss on the resistor, as well as changes in the timing sequence of AC-DC difference tests, relay dead-times, warmup times and voltage level dependence are described.<>
Keywords
ageing; dielectric losses; high-voltage techniques; transducers; voltage measurement; 100 kHz; 500 V; AC-DC difference characteristics; AC-DC difference tests; aging; dielectric loss; high-voltage thermal voltage converters; relay dead-times; timing sequence; voltage level dependence; warmup times; Analog-digital conversion; Capacitance; Dielectric losses; Frequency; Laboratories; NIST; Relays; Resistors; Thermal resistance; Voltage;