DocumentCode
2185708
Title
Calibration of rf field strength meters
Author
de Vreede, J.P.M. ; Teunisse, G.M. ; Munter, K. ; Hoitink, H. ; Holland, K. ; O´Dwyer, M. ; Bergsten, L. ; Puranen, L.
Author_Institution
NMi Van Swinden Lab., Delft, Netherlands
fYear
1994
fDate
June 27 1994-July 1 1994
Firstpage
378
Lastpage
379
Abstract
A BCR intercomparison of field strength meters was performed during 1991-1993 over the frequency range 100 kHz to 1000 MHz and field strength range 1 V/m to 10 V/m. Using different calibration techniques. Four field sensors, electric as well as magnetic, have been used. If certain procedures are followed, a calibration uncertainty of less than 1 dB can be obtained.<>
Keywords
calibration; electric variables measurement; field strength measurement; measurement standards; microwave measurement; 100 kHz to 1000 MHz; BCR intercomparison; EMC; Finland; Germany; Ireland; Netherlands; RF field strength meters; Sweden; Switzerland; UK; calibration techniques; travelling standards; Calibration; Electromagnetic compatibility; Electronics industry; Immunity testing; Laboratories; Magnetic field measurement; Magnetic sensors; Measurement standards; Probes; Radio frequency;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements, 1994. Digest., 1994 Conference on
Conference_Location
Boulder, CO, USA
Print_ISBN
0-7803-1984-2
Type
conf
DOI
10.1109/CPEM.1994.333348
Filename
333348
Link To Document