• DocumentCode
    2186969
  • Title

    Measurements of high voltage impulses (400 kV): implementation of a calibration test procedure

  • Author

    Blanc, I.

  • Author_Institution
    BNM/LCIE, Fontenay-aux-Roses, France
  • fYear
    1994
  • fDate
    June 27 1994-July 1 1994
  • Firstpage
    297
  • Lastpage
    298
  • Abstract
    This paper deals with the implementation of a new chain of calibration for high voltage lightning impulses up to 400 kV. Firstly, the definition and the characterization of a reference measuring system were studied. Then, different methods and procedures have been developed. Finally, the implementation of a calibration test procedure is validated with a metrological point of view.<>
  • Keywords
    high-voltage techniques; lightning protection; measurement standards; overvoltage; power system protection; voltage measurement; 400 kV; HV; calibration test; different method; high voltage impulses; high voltage lightning impulses; measurement standards; reference measuring system; traceability; Calibration; Circuit testing; Frequency; Impulse testing; Lightning; Low voltage; Measurement standards; Stress; Surges; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 1994. Digest., 1994 Conference on
  • Conference_Location
    Boulder, CO, USA
  • Print_ISBN
    0-7803-1984-2
  • Type

    conf

  • DOI
    10.1109/CPEM.1994.333393