DocumentCode :
2187135
Title :
Aspects of the bulk current immunity test
Author :
Burbidge, R.F. ; Edwards, D.J. ; Railton, C.J. ; Williams, D.J.
Author_Institution :
Bristol Univ., UK
fYear :
1990
fDate :
28-31 Aug 1990
Firstpage :
162
Lastpage :
168
Abstract :
Susceptibility measurements pose extreme problems when the vehicle of interest is physically large as the case of aircraft. It is usually impractical to subject the equipment under test (EUT) to very high level electromagnetic fields in the open, in its operational mode. It is generally equally impractical to find a suitable enclosure within which well-conditioned high-level fields can be generated. A method currently being used to overcome this problem in the aircraft industry and elsewhere has been called bulk current injection. This involves injecting current into groups of cables entering ports of a selected part of the system being tested. This injection is carried out using a suitable form of magnetic coupling, between the signal source and the cable harnesses
Keywords :
electric current measurement; field strength measurement; interference suppression; aircraft; bulk current immunity test; bulk current injection; cable harnesses; cables; electromagnetic fields; equipment under test; magnetic coupling; signal source;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Electromagnetic Compatibility, 1990. Seventh International Conference on
Conference_Location :
York
Print_ISBN :
0-85296-001-8
Type :
conf
Filename :
98050
Link To Document :
بازگشت