DocumentCode :
21879
Title :
Pulsed Eddy Current Testing of Thermally Aged and Cold-Rolled Fe–Cu Alloys
Author :
Gui Yun Tian ; Morozov, Mikhail ; Takahashi, Satoshi
Author_Institution :
Sch. of Electr. & Electron. Eng., Newcastle Univ., Newcastle upon Tyne, UK
Volume :
49
Issue :
1
fYear :
2013
fDate :
Jan. 2013
Firstpage :
517
Lastpage :
523
Abstract :
In this work, Fe-1wt%Cu alloy samples exposed to thermal aging and cold rolling (CR) were studied as an attempt to emulate material degradation in neutron irradiated nuclear reactor pressure vessels. CR was tested by pulsed eddy currents (PECs) using a directional probe which was rotated in the sample plane. Normalized PEC signals, represented by typical “figure of eight” on the polar plot, showed very strong anisotropy, which has a monotonic dependence on the amount of cold work. Since the normalized PEC signals represent the response due to electrical conductivity and reduce the ferromagnetic effect, it is concluded that the change is due to anisotropic magnetoresistivity of the rolled steel. The normalized difference PEC responses have been found to be described by the quadratic dependence of the cosine of in-plane angle shifted by an angle, which is believed to correspond to slip planes of dislocations induced by rolling. The technique advantageously combines effects of rolling on electrical conductivity and magnetic permeability and does not require referencing to an untreated standard, which is important for future material and device health management.
Keywords :
ageing; cold rolling; copper alloys; eddy current testing; electrical conductivity; ferromagnetic materials; iron alloys; magnetic anisotropy; magnetic permeability; magnetoresistance; slip; anisotropic magnetoresistivity; cold rolling; cold working; directional probe; dislocations; electrical conductivity; ferromagnetic effect; iron-copper alloys; magnetic anisotropy; magnetic nondestructive evaluation; magnetic permeability; material degradation; monotonic dependence; neutron irradiated nuclear reactor pressure vessels; normalized PEC signals; pulsed eddy current testing; quadratic dependence; rolled steel; slip planes; thermal ageing; Aging; Coercive force; Conductivity; Magnetic hysteresis; Materials; Metals; Permeability; Health management; magnetic nondestructive evaluation (NDE); material aging monitoring; pulsed eddy current (PEC);
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.2012.2206397
Filename :
6227357
Link To Document :