DocumentCode
2188425
Title
International comparisons at low voltage (0.001 V) and high voltage (100 V) in coaxial line at 30 MHz
Author
Janik, D. ; Xi De-Xiong ; John, D. ; Valkeapaa, T. ; Rebuldela, G. ; Rustagi, V.K. ; Sass, J.
Author_Institution
Physikalisch Tech. Bundesanstalt, Braunschweig, Germany
fYear
1994
fDate
June 27 1994-July 1 1994
Firstpage
283
Lastpage
284
Abstract
At a frequency of 30 MHz, (i) two micropotentiometers (0.001 V) have been intercompared between ASMW, OMH, NIM, NIST, NPL (India), PTB, TF and (ii), in a second exercise two thermal converters (100 V) between NIST, NPL (India) and PTB. In this paper, the methods for determining the RF-DC transfer difference are described and the results of the intercomparisons are presented.<>
Keywords
coaxial cables; measurement standards; potentiometers; voltage measurement; 0.001 V; 100 V; 30 MHz; ASMW; India; NIM; NIST; NPL; OMH; PTB; RF-DC transfer difference; TF; international comparison; micropotentiometers; thermal converters; Attenuators; Coaxial components; Connectors; Laboratories; Low voltage; Measurement standards; Metrology; NIST; Radio frequency; Telecommunications;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements, 1994. Digest., 1994 Conference on
Conference_Location
Boulder, CO, USA
Print_ISBN
0-7803-1984-2
Type
conf
DOI
10.1109/CPEM.1994.333447
Filename
333447
Link To Document