Abstract :
At a frequency of 30 MHz, (i) two micropotentiometers (0.001 V) have been intercompared between ASMW, OMH, NIM, NIST, NPL (India), PTB, TF and (ii), in a second exercise two thermal converters (100 V) between NIST, NPL (India) and PTB. In this paper, the methods for determining the RF-DC transfer difference are described and the results of the intercomparisons are presented.<>
Keywords :
coaxial cables; measurement standards; potentiometers; voltage measurement; 0.001 V; 100 V; 30 MHz; ASMW; India; NIM; NIST; NPL; OMH; PTB; RF-DC transfer difference; TF; international comparison; micropotentiometers; thermal converters; Attenuators; Coaxial components; Connectors; Laboratories; Low voltage; Measurement standards; Metrology; NIST; Radio frequency; Telecommunications;