Series elasticity of the human triceps surae muscle: measurement by controlled-release vs. resonance methods
Author :
Hof, A.L.
Author_Institution :
Dept. of Med. Physiol., Groningen Univ., Netherlands
Volume :
2
fYear :
1996
fDate :
31 Oct-3 Nov 1996
Firstpage :
549
Abstract :
With a newly developed Controlled-Release Ergometer the complete characteristic of the series elastic component can be measured in human muscles. Previous estimates were based on the resonance method: muscle elasticity was assessed from the resonance frequency of the muscle elasticity connected to a known mass. In this study both methods have been compared. It turns out that the resonance method gives elasticity values of the correct order of magnitude, but that it is not accurate enough to provide individual data or indications on the course of the series elastic characteristic of the human ankle plantarflexors (m. triceps surae)
Keywords :
biomechanics; biomedical measurement; elasticity; mechanical variables measurement; muscle; resonance; controlled-release ergometer; controlled-release method; human ankle plantarflexors; muscle biomechanical properties; resonance method; series elastic component; series elasticity measurement; Anthropometry; Elasticity; Force measurement; Frequency estimation; Hospitals; Humans; Muscles; Physiology; Resonance; Resonant frequency;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 1996. Bridging Disciplines for Biomedicine. Proceedings of the 18th Annual International Conference of the IEEE
Conference_Location :
Amsterdam
Print_ISBN :
0-7803-3811-1
Type :
conf
DOI :
10.1109/IEMBS.1996.651858
Filename :
651858
Link To Document :
بازگشت