• DocumentCode
    2191797
  • Title

    Pulse shape simulation and analysis of segmented Ge detectors for position extraction

  • Author

    Kurokawa, Meiko ; Shimoura, Susumu ; Iwasaki, Hironori ; Baba, Hidetada ; Michimasa, Shin Ichiro ; Ota, Shinsuke ; Murakami, Hiroyuki ; Sakai, Hideyuki

  • Author_Institution
    Center for Nucl. Study, Univ. of Tokyo, Saitama, Japan
  • Volume
    1
  • fYear
    2002
  • fDate
    10-16 Nov. 2002
  • Firstpage
    369
  • Abstract
    A simulation method, which can predict the relation between the pulse shapes and the interacting points of incident γ-rays, has been established for the entire effective volume of the detector, and its accuracy was experimentally confirmed. Based on the simulated results, the method of pulse shape analysis for the extraction of the position information and the expected resolution are discussed.
  • Keywords
    gamma-ray detection; germanium radiation detectors; position sensitive particle detectors; γ-rays; Ge; position resolution; pulse shapes; segmented Ge detectors; Analytical models; Data mining; Detectors; Energy resolution; Face detection; Physics; Predictive models; Pulse shaping methods; Sensor arrays; Shape;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2002 IEEE
  • Print_ISBN
    0-7803-7636-6
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2002.1239335
  • Filename
    1239335