DocumentCode :
2194965
Title :
Evaluation of the impact of 4D reconstruction algorithms in quantitative dynamic SPECT
Author :
Narayanan, Manoj V. ; Licho, Robert ; Farncombe, Troy H. ; King, Michael A. ; Pretorius, P. Hendrik
Author_Institution :
Med. Sch., Massachusetts Univ., Boston, MA, USA
Volume :
2
fYear :
2002
fDate :
10-16 Nov. 2002
Firstpage :
1023
Abstract :
In this work, we investigated the potential for improving image quality and quantitative accuracy of dynamic Altropane SPECT scans. We evaluated fully-4D reconstruction techniques as well as conventional frame-by-frame reconstruction approaches and their ability to provide consistent striatal binding ratios for both normal and patients with attention deficit hyperactivity disorder (ADHD). We also used the Zubal brain phantom to compare the different reconstruction strategies. A 3-headed Picker-3000 SPECT system fitted with low-energy ultrahigh resolution fan-beam collimators acquired 10 frames of dynamic SPECT data in 4-min acquisitions over a period of 40 minutes. Each set of 128 × 128 projections were acquired at 120 angles over 360°. The dynamic data sequence was using two conventional frame-by-frame reconstruction methods namely, filtered back-projection (FBP) with multiplicative Chang attenuation correction (AC) and re-scaled block-iterative expectation-maximization (RBI-EM) with uniform AC. We also considered two fully-4D reconstructions methods, the KL-EM that exploits the Karbunen-Loeve transform (or principal component analysis) and a dynamic expectation maximization algorithm or DSPECT that incorporates dynamic inequality constraints in the reconstructed object voxel activity over time. Both 4D methods were implemented with uniform AC. From the results, it is clear that both the 4D methods are more robust in handling the low-count dynamic data. However, derived parameters such as the binding ratio might be more insensitive to noise, although in the patient study FBP binding ratios differed greatly from that of the other reconstruction strategies.
Keywords :
principal component analysis; single photon emission computed tomography; 4D reconstruction; 4D reconstruction algorithms; Karbunen-Loeve transform; Zubal brain phantom; attention deficit hyperactivity disorder; filtered back-projection; frame-by-frame reconstruction; image quality; multiplicative Chang attenuation correction; principal component analysis; quantitative dynamic SPECT; re-scaled block-iterative expectation-maximization; striatal binding ratios; Attenuation; Collimators; Heuristic algorithms; Image quality; Image reconstruction; Imaging phantoms; Noise robustness; Principal component analysis; Reconstruction algorithms; Signal to noise ratio;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2002 IEEE
Print_ISBN :
0-7803-7636-6
Type :
conf
DOI :
10.1109/NSSMIC.2002.1239496
Filename :
1239496
Link To Document :
بازگشت