Title :
Comparison of radiated immunity tests in different EMC test facilities
Author :
Streitwolf, Holger ; Heinrich, Ralf ; Behnke, Heinz-Günther ; Dallwitz, Lothar ; Karsten, Uwe
Author_Institution :
Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin, Deutschland
Abstract :
This paper reports about investigations of different EMC test facilities from immunity point of view. A special test device has been developed in order to obtain a quantitative measure for the immunity test. Using this test device different test facilities are compared regarding their repeatability and reproducibility as well as other advantages and drawbacks.
Keywords :
Anechoic chambers; Battery charge measurement; Distortion measurement; Electromagnetic compatibility; IEC standards; Immunity testing; Radio frequency; Reproducibility of results; Reverberation chamber; Test facilities;
Conference_Titel :
Electromagnetic Compatibility, 2007. EMC Zurich 2007. 18th International Zurich Symposium on
Conference_Location :
Munich, Germany
Print_ISBN :
978-3-9523286-1-3
Electronic_ISBN :
978-3-9523286-0-6
DOI :
10.1109/EMCZUR.2007.4388237