DocumentCode :
2201082
Title :
Use of reduced order models to calculate reclosing transients in a refinery
Author :
Pillay, P. ; Sabur, S.M.A.
Author_Institution :
Dept. of Electr. Eng., New Orleans Univ., LA, USA
Volume :
3
fYear :
1995
fDate :
8-12 Oct 1995
Firstpage :
2180
Abstract :
The DQ/dq model has been widely used to study single machine transients but it is difficult to use for multimachines during unbalanced faults when the effects of source impedance must be included. In this paper, a hybrid model (ABC/dq) of an induction motor is used in order to analyze the reclosing transients of several hundred critical motors in a refinery. These results are compared with the results from a reduced order model with a significant reduction in computational burden. The correlation is satisfactory
Keywords :
electric impedance; induction motors; industrial power systems; machine theory; oil refining; power system transients; transient analysis; DQ/dq model; impedance source; reclosing transients calculation; reduced order models; refinery; unbalanced faults; Circuit faults; Equations; Impedance; Inductance; Induction motors; Mathematical model; Reduced order systems; Rotors; Stators; Transient analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industry Applications Conference, 1995. Thirtieth IAS Annual Meeting, IAS '95., Conference Record of the 1995 IEEE
Conference_Location :
Orlando, FL
ISSN :
0197-2618
Print_ISBN :
0-7803-3008-0
Type :
conf
DOI :
10.1109/IAS.1995.530580
Filename :
530580
Link To Document :
بازگشت