• DocumentCode
    2201386
  • Title

    Uncertainty contributions to the clamp factor CF of the absorbing clamp

  • Author

    Ryser, Heinrich

  • Author_Institution
    EMC Laboratory, Swiss Federal Office of Metrology METAS, Lindenweg 50, CH-3003 Bern-Wabern, Switzerland
  • fYear
    2007
  • fDate
    24-28 Sept. 2007
  • Firstpage
    385
  • Lastpage
    388
  • Abstract
    This contribution reports on experimental investigations on different uncertainty contributions to the result of the absorbing clamp calibration. The requirements in [1] are confirmed and some additional precautions are described which can further reduce the uncertainty of the calibration.
  • Keywords
    Calibration; Clamps; Electromagnetic compatibility; Ferrites; Impedance measurement; Position measurement; Reproducibility of results; Testing; Uncertainty; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2007. EMC Zurich 2007. 18th International Zurich Symposium on
  • Conference_Location
    Munich, Germany
  • Print_ISBN
    978-3-9523286-1-3
  • Electronic_ISBN
    978-3-9523286-0-6
  • Type

    conf

  • DOI
    10.1109/EMCZUR.2007.4388276
  • Filename
    4388276