DocumentCode
2201386
Title
Uncertainty contributions to the clamp factor CF of the absorbing clamp
Author
Ryser, Heinrich
Author_Institution
EMC Laboratory, Swiss Federal Office of Metrology METAS, Lindenweg 50, CH-3003 Bern-Wabern, Switzerland
fYear
2007
fDate
24-28 Sept. 2007
Firstpage
385
Lastpage
388
Abstract
This contribution reports on experimental investigations on different uncertainty contributions to the result of the absorbing clamp calibration. The requirements in [1] are confirmed and some additional precautions are described which can further reduce the uncertainty of the calibration.
Keywords
Calibration; Clamps; Electromagnetic compatibility; Ferrites; Impedance measurement; Position measurement; Reproducibility of results; Testing; Uncertainty; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 2007. EMC Zurich 2007. 18th International Zurich Symposium on
Conference_Location
Munich, Germany
Print_ISBN
978-3-9523286-1-3
Electronic_ISBN
978-3-9523286-0-6
Type
conf
DOI
10.1109/EMCZUR.2007.4388276