• DocumentCode
    2201863
  • Title

    An Indirect Alternative Method of Measurement for Conducted Emissions of High-Power Equipments

  • Author

    Coets, Stephane ; Beauvois, Veronique

  • Author_Institution
    Dept. of Electrical Engineering and Computer Science, Montefiore Institute, University of Liege, Belgium
  • fYear
    2007
  • fDate
    24-28 Sept. 2007
  • Firstpage
    477
  • Lastpage
    480
  • Abstract
    This paper deals with a novel indirect measurement method using a “virtual” LISN to get normalised, reproducible and accurate results. According to the CISPR 16-2-1 standard [1], in the low frequency range, conducted emission measurements should be performed on power supply lines either with a Line Impedance Stabilized Network (LISN) or with a passive voltage probe. However both methods have drawbacks in terms of accuracy, feasibility, etc. This paper briefly compares different direct alternative methods of conductive emission measurement in case of high-power equipements. Furthermore, a new indirect method of measurement based on the research of a simple and stable EUT model and using a “virtual” LISN is presented.
  • Keywords
    Circuit noise; Electric variables measurement; Filters; Impedance measurement; Measurement standards; Performance evaluation; Power measurement; Power supplies; Probes; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2007. EMC Zurich 2007. 18th International Zurich Symposium on
  • Conference_Location
    Munich, Germany
  • Print_ISBN
    978-3-9523286-1-3
  • Electronic_ISBN
    978-3-9523286-0-6
  • Type

    conf

  • DOI
    10.1109/EMCZUR.2007.4388299
  • Filename