DocumentCode
2205245
Title
Particle Accelerator Cavity Design
Author
Matlocha, T. ; Skvor, Z.
Author_Institution
Dept. Electromagn. Field, Czech Tech. Univ. in Prague, Prague
fYear
2008
fDate
23-24 April 2008
Firstpage
1
Lastpage
4
Abstract
This paper deals with a class of quarter- wave particle accelerator resonating structures. The structure has been modeled as a cascade composed of several transmission line sections. Resonant frequency, total power loss, longitudinal voltage and current distribution as well as efficiency ratio are calculated and discussed. Theoretical results are used in resonator design, and verified using a downscaled model. Using of the presented method is not restricted to any geometry of analyzed transmission line.
Keywords
accelerator cavities; biomedical equipment; cavity resonators; radiation therapy; radioisotope imaging; current distribution; particle accelerator cavity design; quarter-wave particle accelerator; resonant frequency; resonating structure; Bismuth; Cyclotrons; Impedance; Linear particle accelerator; Nuclear physics; Power transmission lines; Production; Transmission line theory; Transmission lines; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Techniques, 2008. COMITE 2008. 14th Conference on
Conference_Location
Prague
Print_ISBN
978-1-4244-2137-4
Electronic_ISBN
978-1-4244-2138-1
Type
conf
DOI
10.1109/COMITE.2008.4569902
Filename
4569902
Link To Document