Title :
Hg density imaging in a metal-halide arc lamp
Author :
Curry, J.J. ; Adler, H.G.
Author_Institution :
Nat. Inst. of Stand. & Technol., Gaithersburg, MD, USA
Abstract :
Summary form only given, as follows. We will report initial results from the imaging of Hg vapor in a metal-halide arc lamp using synchrotron x-ray radiation. These measurements extend previous work on X-ray absorption imaging in arc lamps using an X-ray tube. High flux synchrotron radiation and a digital detector make it possible to obtain time-resolved measurements. Monochromatic radiation improves the accuracy over what can be obtained with broadband radiation.
Keywords :
arc lamps; mercury (metal); mercury vapour lamps; plasma density; plasma diagnostics; Hg density imaging; X-ray absorption imaging; X-ray tube; broadband radiation; digital detector; high flux synchrotron radiation; metal-halide arc lamp; monochromatic radiation; synchrotron X-ray radiation; time-resolved measurements; Arc discharges; Cathodes; Lamps; Mercury (metals); Optical imaging; Plasma measurements; Plasma temperature; Surface discharges; Synchrotron radiation; X-ray imaging;
Conference_Titel :
Plasma Science, 2002. ICOPS 2002. IEEE Conference Record - Abstracts. The 29th IEEE International Conference on
Conference_Location :
Banff, Alberta, Canada
Print_ISBN :
0-7803-7407-X
DOI :
10.1109/PLASMA.2002.1030423