Title :
Design and operation of a two-color, four-beam fiber optic interferometer
Author :
McFarland, M. ; Niansheng Qi ; Xiaoxi Xu ; Prasad, R.R. ; Gensler, S. ; Krishnan, Mohan
Author_Institution :
Almeda Appl. Sci. Corp., San Leandro, CA, USA
Abstract :
Summary form only given, as follows. A novel two-color, four-beam fiber optic interferometer (FOI) has been designed and built. This instrument is unique because it uses standard fiber optic components in its construction, which allows for an inexpensive yet sophisticated design. Wavelength division multiplexers are used to combine two separated wavelengths, 1550 nm and 1310 nm, into a single fiber, which is then fed to a collimator and passed through the medium to be measured. Four independent beams of two colors each are available in the instrument. Each color and beam uses a feedback loop to drive a piezo-electric fiber stretcher (total of eight) to counter the effects of acoustic vibrations. The use of two wavelengths allows both the electron density and the neutral density to be measured simultaneously. The design sensitivity of the instrument is less than 7/spl times/10/sup 13/ cm/sup -2/ for electrons and less than 6/spl times/10/sup 15/ m/sup -2/ for neutrals. Sample data is presented which show the results of measurements preformed on pre-ionized gas puff valves and opening switch plasmas.
Keywords :
electron density; fibre optic sensors; light interferometers; optical collimators; optical design techniques; optical feedback; plasma density; plasma devices; plasma diagnostics; plasma switches; sensitivity; valves; wavelength division multiplexing; 1310 nm; 1550 nm; acoustic vibrations; collimator; design; design sensitivity; electron density; feedback loop; four-beam fiber optic interferometer; independent beams; inexpensive yet sophisticated design; neutral density; neutrals; opening switch plasmas; piezo-electric fiber stretcher; pre-ionized gas puff valves; sample data; separated wavelengths; single fiber; standard fiber optic components; two-color fiber optic interferometer; two-color four-beam fiber optic interferometer; wavelength division multiplexers; Acoustic beams; Acoustic measurements; Electrons; Instruments; Optical design; Optical fibers; Plasma measurements; Structural beams; Switches; Wavelength measurement;
Conference_Titel :
Plasma Science, 2000. ICOPS 2000. IEEE Conference Record - Abstracts. The 27th IEEE International Conference on
Conference_Location :
New Orleans, LA, USA
Print_ISBN :
0-7803-5982-8
DOI :
10.1109/PLASMA.2000.855036