• DocumentCode
    2211342
  • Title

    Quantitative analysis of an urban effect against the electromagentic induction onto telecommunication line by electricfied railway line based on field measurements

  • Author

    Lee, Sangmu ; Choi, Munhwan ; Cho, Pyung-Dong

  • Author_Institution
    Electron. & Telecommun. Res. Institue, Daejeon, South Korea
  • fYear
    2010
  • fDate
    11-13 Aug. 2010
  • Firstpage
    289
  • Lastpage
    293
  • Abstract
    Field measurements were carried out to scrutinize an urban effect against electromagnetic induction by power line onto telecommunication line. 35 selected places´ data gathered from each rural and city areas are comparatively analyzed to know the quantitative factor with shielding effect of urban area over countrysides. The shielding coefficient has been resulted into 0.6 of cities over rurals which means that the induced voltages are averagely 40% lower in the urban area than rural area.
  • Keywords
    electromagnetic induction; electromagnetic shielding; power overhead lines; railway electrification; telecommunication transmission lines; city areas; electrified railway line; electromagnetic induction; field measurements; power line; rural areas; shielding coefficient; shielding effect; telecommunication line; urban effect; Area measurement; Cities and towns; Communications technology; Materials; Urban areas; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applications of Electromagnetism and Student Innovation Competition Awards (AEM2C), 2010 International Conference on
  • Conference_Location
    Taipei
  • Print_ISBN
    978-1-4244-6416-6
  • Type

    conf

  • DOI
    10.1109/AEM2C.2010.5578793
  • Filename
    5578793