Abstract
Faraday´s induction experiment in a nanometer scale is presented. A nano-transformer with the coupling area of approximately 1mum2 was fabricated, and the induced open circuit voltage as functions of the frequency and the magnitude of the input bias were measured. Our measured results show that the transformer behaves as a linear ideal transformer with the mutual inductance of 30 nil. This mutual inductance value is orders of magnitude larger than the one expected from 1mum2 coupling area.
Keywords
nanotechnology; transformers; Faraday induction; induced open circuit voltage; linear ideal transformer; nanotransformer; Coupling circuits; Electromagnets; Frequency; Inductance; Magnetic cores; Magnetic field measurement; Magnetic flux; Nanobioscience; Quantum computing; Voltage; Faraday; induction; nano; transformer;