Comparison of energy window choice and parameter implementation in dual energy window scatter correction performance in 3D PET
Author :
Sossi, V. ; Barney, JS ; Oakes, TR ; Ruth, TJ
Author_Institution :
British Columbia Univ., Vancouver, BC, Canada
Abstract :
The authors have investigated the relevance of the energy window choice in the dual energy window (DEW) scatter correction method (Grootoenk et al., 1991). This method depends strongly on the difference between 2 parameters that need to be estimated from phantom studies, the ratio (Runsc) between the true events in the low energy window (LEW) and high energy window (HEW), and the equivalent ratio for the scattered events (Rsc). The transaxial distribution of the Runsc is relatively flat regardless of the energy window selection. However, the energy window choice considerably influences the transaxial distribution of Rsc. Since the DEW scatter correction method does not make use of convolution techniques, spatial variations of parameters are expected to lead to nonuniformities in scatter corrected images. The authors have investigated the DEW scatter correction accuracy and uniformity as a function of energy window choice and determination of Rsc. Based on stability considerations 2 sets of energy windows have been selected for study, 100-350-850 keV and 250-380-850 keV. Three methods to implement the Rsc values in the scatter correction estimate have been used: an array containing the transaxial distribution of Rsc; a constant value obtained by averaging Rsc, over the central 20 cm diameter region; and a constant value corresponding to the central Rsc value. The use of constant values for Rsc improved image uniformity for both sets of energy windows from within 30% obtained when the array for Rsc was used, to about 15%. The uniformity was estimated over a 20 cm diameter region. Scatter correction accuracy as determined from uniform phantom and cold spot studies was comparable in all cases. No significant difference in transaxial or axial image uniformity was observed between data obtained with the 2 sets of energy windows and normalized with the present normalization algorithm. Likewise the accuracy obtained in both cases was comparable, indicating that the implementation method of the Rsc is a more important factor in the DEW scatter correction method performance than the selection of energy windows
Keywords :
gamma-ray scattering; medical image processing; positron emission tomography; 100 to 850 keV; 20 cm; 3D PET; axial image uniformity; cold spot studies; dual energy window scatter correction performance; energy window choice; medical diagnostic imaging; normalization algorithm; nuclear medicine; parameter implementation; transaxial distribution; transaxial uniformity; uniform phantom; uniformity; Convolution; Current measurement; Energy measurement; Event detection; Hospitals; Imaging phantoms; Positron emission tomography; Scattering parameters; Stability; Water resources;
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference Record, 1995., 1995 IEEE
Conference_Location :
San Francisco, CA
Print_ISBN :
0-7803-3180-X
DOI :
10.1109/NSSMIC.1995.510447