Abstract :
To research the effect of temperature and humidity on corona performance of UHV DC transmission line, a mini corona cage has been constructed and put in a manual environment room, which temperature and humidity can be controlled. At the same time, a corona performance measuring system by using vary methods such as current impule method, acoustic method have been set up too. The corona inception corona voltage gradient of a copper line have been measured in a mini corona cage not only at different absolute humidity from 3 g/m3 to 12 g/m3 but also at different temperature from 0degC to 35degC . The relationship between inception corona voltage gradient and temperature and humidity have been achieved.
Keywords :
HVDC power transmission; corona; humidity control; power transmission lines; temperature control; UHV DC transmission line; corona voltage gradient; humidity control; temperature control; Acoustic measurements; Copper; Corona; Current measurement; Humidity control; Temperature control; Time measurement; Transmission line measurements; Transmission lines; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation, 2008. ISEI 2008. Conference Record of the 2008 IEEE International Symposium on
Conference_Location :
Vancouver, BC
ISSN :
1089-084X
Print_ISBN :
978-1-4244-2091-9
Electronic_ISBN :
1089-084X
Type :
conf
DOI :
10.1109/ELINSL.2008.4570279
Filename :
4570279
Link To Document :
بازگشت