DocumentCode :
2212349
Title :
Field uniformity in radiated field immunity tests
Author :
Audone, Bruno ; Colombo, Roberto ; Borsero, Michele
Author_Institution :
EMC, Torino, Italy
fYear :
2015
fDate :
16-22 Aug. 2015
Firstpage :
914
Lastpage :
919
Abstract :
The calibration requirements of radiated immunity tests performed in semi-anechoic chambers and fully anechoic rooms are analyzed by means of electromagnetic computational tools to verify the severity of the allowed tolerance requirements of their anechoic environments. Some proposals of alternative figures of merit directly related to the electric field distribution in the test area or volume are illustrated taking into account the need of proposing system metrics capable of rendering radiated immunity tests comparable, reliable and repeatable.
Keywords :
Eigenvalues and eigenfunctions; Electric fields; Immunity testing; Standards; Transducers; Transmitting antennas;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility (EMC), 2015 IEEE International Symposium on
Conference_Location :
Dresden, Germany
Print_ISBN :
978-1-4799-6615-8
Type :
conf
DOI :
10.1109/ISEMC.2015.7256287
Filename :
7256287
Link To Document :
بازگشت