• DocumentCode
    2212493
  • Title

    A Cryogenic Microwave Measuring System for Satellite Receiver Testing

  • Author

    Sjöman, P. ; Hughes, N.J. ; Jukkala, P. ; Ovaska, S. ; Tuovinen, J. ; Kangaslahti, P. ; Eskelinen, P.

  • Author_Institution
    Helsinki University of Technology, Mets?hovi Radio Research Station, Mets?hovintie 114, 02540 KYLM?L?, FINLAND; Ylinen Electronics Ltd., FINLAND. Email: psj@kurp.hut.fi
  • fYear
    2003
  • fDate
    Oct. 2003
  • Firstpage
    81
  • Lastpage
    83
  • Abstract
    A cryogenic microwave test system for the 70 GHz Planck satellite receiver has been built. It consists of 4 K and 20 K active helium coolers mounted in large 2× 10¿7 mbar vacuum chamber. Special RF-components have been designed for the tests, e.g. a 4 K load for the continuous comparator reference temperature stimulus. External electronics has been constructed to measure the two orthogonal polarizations from two parallel receiver units. The noise temperature measurement uncertainty is better than 4 K and the test system´s post-detection noise characteristics with a matched load is better than 1.6.10¿6 V/¿Hz from 15 mHz, when the integration time constant is 0.5 s.
  • Keywords
    Cryogenics; Electronic equipment testing; Microwave measurements; Microwave technology; Polarization; Receivers; Satellite broadcasting; System testing; Temperature measurement; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Conference, 2003 33rd European
  • Conference_Location
    Munich, Germany
  • Print_ISBN
    1-58053-834-7
  • Type

    conf

  • DOI
    10.1109/EUMA.2003.340895
  • Filename
    4142959