Title :
Low-frequency magnetic-field immunity surface scan method
Author :
Coenen, Mart ; Kathari, Bharat
Author_Institution :
EMCMCC, Breda, the Netherlands
fYear :
2015
fDate :
16-22 Aug. 2015
Firstpage :
1022
Lastpage :
1025
Abstract :
Many sensor designs incorporating electronics are becoming more vulnerable to low frequency (LF) magnetic field (H-fields) when used in close proximity of electrically driven actuators, linear and rotating motors. The complex geometrical structure of the sensor´s front-end design is often unknown. The sensor´s front-end position is where the physical measurement quantity is transferred into an electrical quantity and then led up to the amplification stages. Again, given by the fact that low-frequency H-fields are hard to shield, the externally generated H-fields i.e. magnetic flux penetrates into the few sub-mm square area and induces interfering voltages: U = −dφ/dt = −dB.A/dt.
Keywords :
Actuators; Harmonic analysis; Magnetic flux; Magnetic heads; Probes; Sensitivity; Sensor systems; H-field; presystem integration analysis; sensitivity; sensors; signal integrity;